
Recessed trunking
The RH2 profile fits discreetly into furniture thanks to its shallow depth (34 mm), without a cable compartment. A slim and sober solution for near-invisible integration into your tables, desks, and business corners.
5 products
Sort by:
5 products
Custom lengths for your furniture and large meeting tables
Create an integrated electrical installation for your furniture. The RH2 trunking can be cut to fit the furniture, then accepts SFC3 electrical segments in the required locations. Complete the non-electrified sections with SFC2D blanking panels cut to the desired length. A solution designed for offices, workstations, and large meeting room tables.
A modular design adapted for recessed installation
Just like the SH1 trunking, you choose the areas to electrify and the sections to blank off. With the RH2, the project remains integrated into the furniture.
A blank trunking to configure
Supplied in a cuttable 150 cm length, the trunking forms the profile of your installation. SFC3 segments, SFC2D blanking panels, end caps, and other necessary components must be selected separately.
A furniture-recessed project
Adapt the length and the distribution of electrified areas to your furniture or table. The RH2 is not presented as a room-perimeter solution: its use is focused on integration into furniture.
Configure the useful areas of your table
Large meeting tables
Provide electrified areas where participants need to plug in their devices. The intermediate sections are closed with SFC2D.
Desks and workstations
Integrate a length adapted to the furniture and place the SFC3 segments according to the workstation layout.
Custom-built furniture
Configure the installation according to the furniture dimensions and power requirements, without electrifying the entire length.
A discreet but visible finish
The recess width is 7 cm, for a total profile width of 8 cm. After installation, it protrudes 2 mm from the support: it is therefore neither invisible nor completely flush.
How to combine SFC3, SFC2D and DS4?
| Component | Role in your installation |
|---|---|
| RH2 trunking | Aluminium profile designed to be recessed into furniture. |
| SFC3 electrical segment | Creates the electrified areas designed to receive EUBIQ sockets. |
| SFC2D blanking panel | Closes the non-electrified sections. It can be cut to complete the SFC3 and achieve the desired final length. |
| DS4 for RJ45 | Allows RJ45 sockets to be integrated in a fixed location between two SFC3 segments or at the end of the installation, instead of a section of SFC2D. The RJ45 sockets installed this way cannot be moved along the track. |
| End caps | Close the ends of the profile to complete the installation. |
Example for a large meeting table: provide several SFC3 areas at the locations where participants plug in, then complete the intermediate sections with fitted SFC2D blanking panels. If you want RJ45 connections, reserve their fixed location using DS4 between two SFC3 segments or at the end of the installation, replacing the SFC2D in that location.
RH2 profile specifications
Before machining the furniture: distinguish the 7 cm recess width from the 8 cm total profile width. Check the other dimensions of the housing, clearances, and fixings using the technical documentation and the selected configuration.
Components to provide
Configure your project with the RH2 trunking, SFC3 electrical segments, SFC2D blanking panels, end caps, EUBIQ sockets, and the fixing and connection components suited to your configuration. Add DS4 if you want to integrate RJ45 sockets in fixed locations between two SFC3 segments or at the end of the installation, instead of the SFC2D. The blank trunking is not a pre-power track.
SFC3 areas are designed for EUBIQ sockets, including models corresponding to the different types of sockets by country. They do not directly accept standard wall sockets from other brands.
Prepare your custom installation
Define the location in the furniture
Measure the useful length and check the material, available thickness, fixing, and power supply routing before preparing the housing.
Distribute the electrified areas and RJ45 sockets
Place the SFC3 segments according to the workstations to be powered and provide SFC2D for the remaining sections. For the RJ45 sockets, reserve fixed locations using DS4 between two SFC3 segments or at the end of the installation, instead of a section of SFC2D.
Adjust the lengths
The aluminium trunking is cut with a hacksaw. For a more professional cut, use a circular saw equipped with a blade suited for aluminium. Also cut the SFC2D blanking panels to the required lengths. Secure the pieces, follow the tool's safety instructions, and deburr the edges. Do not confuse these adjustments with cutting the SFC3 electrical segment.
Prepare the housing and fix the profile
Provide a recess width of 7 cm. Follow the other dimensions and requirements of the technical documentation for machining and fixing. The total profile width is 8 cm and, after installation, it protrudes 2 mm from the support.
Assemble and connect
Install the components and end caps according to their documentation. The electrical installation must be carried out without power by a person qualified in electricity.
Frequently asked questions
What is the common point with the SH1 trunking?
The modular design principle is the same: SFC3 areas electrify the useful locations and the cut SFC2D completes the other sections. The RH2 is designed for recessed installation in furniture, while the SH1 is surface-mounted.
Can the installation be adapted to a large meeting table?
Yes. Configure the recessed length according to the furniture dimensions and distribute the electrified areas according to the seats to be served. Prepare the configuration and connection with a person qualified in electricity.
Can RJ45 sockets be added?
Yes, via DS4. The RJ45 sockets are then fixed between two SFC3 segments or at the end of the installation, instead of a section of SFC2D. They cannot be moved along the track: their location must be planned when configuring the installation.
Should the entire length be electrified?
No. SFC2D blanking panels close the sections without an SFC3 segment and are cut to achieve the desired length.
What are the integration dimensions?
The recess width is 7 cm, for a total profile width of 8 cm. It protrudes 2 mm from the support after installation and is therefore not completely flush. Consult the technical documentation for the other dimensions of the housing.
Is the RH2 designed for a partition?
No, it was developed for recessed installation in furniture. Any use in a partition requires a check of the material and the fixing method; it should not be considered compatible by default.
The RH2, to the measure of your furniture.
A recessed length adapted to the furniture and electrified areas where you need them.
Electrify only the useful areas of your installation
The SFC3 is the electrical segment that completes an EUBIQ SH1 or RH2 trunking installation. It creates the power supply zones designed to receive your EUBIQ sockets. It cannot be used on its own: it must be integrated into one of these trunking systems, along with the elements required for your configuration.
An electrification component, not a standalone track
The trunking provides the support
Choose the SH1 for surface-mounted installation, or the RH2 for recessing into furniture. The SFC3 is integrated into the selected trunking; it does not replace it.
The SFC3 creates the electrified zones
Place the segments where you need to power your devices. EUBIQ sockets can be positioned and repositioned on the electrified zones according to their mode of use.
The SFC2D completes the other sections
Close the non-electrified zones with cut-to-size SFC2D covers. The combination of SFC3 segments and the SFC2D allows you to achieve the desired final length.
The DS4s allow you to add RJ45s
RJ45s are installed via the DS4s, between two SFC3 segments or at the end of the installation, in place of a section of SFC2D. They remain fixed and cannot be moved along the track.
What role does each element play?
| Element | Function |
|---|---|
| SH1 or RH2 trunking | Forms the support profile for the installation. |
| SFC3 electrical segment | Electrifies the chosen areas to receive the EUBIQ sockets. Not used on its own. |
| SFC2D cover | Closes the non-electrified sections and is cut to size to adjust the final length. |
| DS4 for RJ45 | Allows fixed RJ45 connections between two SFC3 segments or at the end, in place of the SFC2D. |
| End caps | Close the ends of the trunking. |
| EUBIQ sockets | Positioned on the SFC3 electrified zones to plug in your devices. |
To plan for your project: the SH1 or RH2 trunking, the SFC3 segments, the SFC2D covers, the end caps, the EUBIQ sockets, and the appropriate mounting and connection elements. Add the DS4s for the RJ45s and the accessories required for your configuration.
SH1 surface-mounted or RH2 recessed into furniture?
SH1 trunking — surface-mounted
For custom lengths, corner returns, and room perimeter installations. Electrify only the useful areas with the SFC3 segments and complete the other sections with SFC2D. The SH1 features a compartment for low-voltage cables and a lower groove for kitchen accessories.
RH2 trunking — recessed into furniture
For furniture, desks, and large meeting tables. Recessing width: 7 cm; total profile width: 8 cm; protrusion after recessing: 2 mm. The project remains focused on integration into the furniture, without room perimeter installation.
The RH2 was not developed for partitions. Any potential use in a partition requires checking the support material and the method of fixation, without assuming systematic compatibility.
Choose the length and the connection
The lengths offered on this data sheet are: 50, 60, 70, 90, 100, 110, 130, and 150 cm. Choose the segment according to the area to be electrified in your trunking, then adjust the remaining sections with SFC2D.
Connection: select the configuration offered for your length, "Both sides" or "Left", depending on the available variants. Check this choice before ordering and prepare the connection according to the product documentation.
Technical specifications
The maximum segment value must not be confused with that of each socket or the power supply circuit. Have the sizing of the entire system checked by a qualified electrical professional. For use in dry indoor areas.
Prepare your custom-configured installation
Choose your trunking
Choose the SH1 for surface mounting, or the RH2 for recessing into furniture. Define the dimensions and fixings using the technical documentation.
Distribute the SFC3 zones
Choose the segment lengths and connection configurations based on the locations to be powered.
Complete the remaining sections
Plan for cut-to-size SFC2D to adjust the final length, DS4s for fixed RJ45s, and end caps to finish the trunking. The cover adjustment cuts must not be confused with a cut in the SFC3 electrical segment.
Integrate and connect the components
The quick connector facilitates connection, but does not make the SFC3 standalone. The electrical installation must be carried out de-energized by a qualified electrical professional, following the component documentation.
Position your EUBIQ sockets
After installing and checking the entire system, position the EUBIQ socket on an electrified zone, plug in your device, then activate the socket according to its instructions.
Frequently asked questions
Can the SFC3 be used on its own?
No. It must be integrated into an SH1 or RH2 trunking installation, with the appropriate components and connection. It is not a standalone track ready to install.
What is the difference with the SFC2D?
The SFC3 electrifies the areas intended for EUBIQ sockets. The SFC2D is a cover without an electrical function that closes the other sections and is cut to size to achieve the desired length.
Can several electrified zones be planned?
Yes. You can combine several SFC3 zones in an SH1 or RH2 installation and complete the intervals with SFC2D. The connection of the entire system must be prepared according to the selected components.
Which sockets are compatible?
EUBIQ sockets, including models corresponding to the different types of sockets by country. The SFC3 does not directly receive standard wall sockets from other brands.
Do the RJ45s move like the EUBIQ electrical sockets?
No. The RJ45s are installed via the DS4s in fixed locations, between two SFC3 segments or at the end of the installation, in place of the SFC2D.
How to achieve a custom final length?
Choose the SFC3 lengths according to the areas to be electrified and complete with cut-to-size SFC2D in a suitable trunking. The cover adjustment is distinct from a cut in the electrical segment.
SFC3: the electrification of your custom-configured trunking.
SH1 or RH2 for the support, SFC3 for the powered zones, SFC2D for the sections to be covered.
Complete the non-electrified areas of your EUBIQ installation
The SFC2D is a blind panel with no electrical function, designed for RH2 and SH1 modular trunking. Pair it with SFC3 electrical segments and cut it to close off non-electrified sections and achieve the desired length, with a uniform brushed aluminum finish.
Why choose this blind panel?
Closes off empty spaces
Closes off sections of trunking that are not equipped with SFC3 electrical segments.
Brushed aluminum finish
Visually extends your installation with a neat and discreet finish.
Cut to the desired length
Supplied in 100 cm lengths, the SFC2D can be cut to complete SFC3 segments and adjust the final length of your installation.
Electrify only the useful areas
Reserve SFC3 segments for locations where you want to use your EUBIQ sockets and complete the other sections with SFC2D.
What is a trunking blind panel used for?
A modular installation combines electrified areas created by SFC3 segments and non-electrified sections closed off by the SFC2D. The blind panel makes it possible to adapt the final length to the project without electrifying the entire trunking.
- Closes off empty spaces between SFC3 segments
- Adjusts lengths by cutting the blind panel
- Provides a continuous finish on non-electrified sections
- Compatible with RH2 and SH1 modular trunking
On an SH1 installation, for example, you can create a route with corners or wrap around a room, electrifying only certain areas. SH1 trunking uses the same profile as the SH1 tracks sold in 60, 80, 100, and 120 cm lengths; the modular solution allows you to customize the layout.
Technical specifications
Compatibility: modular trunking
Choose the profile suitable for your layout, then complete its non-electrified areas with the SFC2D.
Recessed into furniture
The RH2 is designed to be recessed into furniture. Its total width is 8 cm, with a 2 mm protrusion after recessing. It was not developed for partitions: this use requires checking the material and method of attachment.
Surface-mounted installation
For a custom wall route, a custom length, or wrapping around a room. Pair the SFC3 segments and SFC2D blind panels to choose the areas to electrify.
To complete the assembly, plan for the trunking, SFC3 segments, SFC2D blind panels, end caps, corners, connectors, and other accessories suitable for the project. The SFC2D closes off non-electrified longitudinal sections; it does not replace end caps.
Brushed aluminum finish
The blind panel completes non-electrified sections without interrupting the appearance of your installation.
Brushed aluminum finish for the closed-off sections.
A 100 cm length to be cut down according to the spaces to be closed.
How to prepare and install the SFC2D?
Measure the lengths to be closed in your RH2 or SH1 trunking, taking into account the planned SFC3 segments.
A hacksaw is suitable. For a more professional cut, use a circular saw equipped with a blade suitable for aluminum. Hold the piece securely, follow the tool's safety instructions, and deburr the edges after cutting. The adjustment described applies to the SFC2D, not the SFC3 electrical segment.
Place the SFC2D in the locations provided by the profile, following the component documentation.
Check the fit with the adjacent segments and plan for the trunking end caps. Any work on the electrical installation must be carried out by a qualified electrician, with the power turned off.
Frequently asked questions
What is the difference between SFC2D and SFC3?
The SFC3 creates an electrified area designed to receive EUBIQ sockets. The SFC2D is a blind panel with no electrical function that closes off the other sections and makes it possible to adjust the final length.
How do I calculate the quantity to order?
Add up the lengths to be closed off, then plan for the cuts in the 100 cm elements. Take into account the distribution of the different sections and the cutting losses, not just the total length.
Can the electrified areas be changed later?
The configuration can be revised by combining the appropriate SFC3 and SFC2D elements. Any electrical modification must be prepared and carried out by a qualified electrician.
Does the SFC2D replace an end cap?
No. It closes off a section of the trunking along its length. End caps are separate elements to be planned for closing off the ends of the profile.
SFC2D: the right length, in the useful places.
Complete your SFC3 segments and ensure a neat finish for your modular installation.
The pair — a neat finish at both ends of the profile
Close the open ends of your EUBIQ RH2 raceway with this pair of dedicated end caps, supplied with fixing screws. They conceal the opening of the profile to neatly finish your installation recessed into furniture, particularly desks and large conference tables.
Why choose dedicated end caps?
Closes the ends
They close the open ends of the RH2 raceway and conceal the interior of the profile at the start and end of the run.
Designed for RH2
Accessories designed for the RH2 profile, to be selected according to the raceway model in your installation.
Sold in pairs, screws included
Two end caps with their fixing screws. Count the open ends to be finished to determine the quantity required.
Two finishes
Choose Aluminium or Black depending on the desired variant and the appearance of your installation.
End cap or SFC2D blanking plate?
SFC2D blanking plate
Closes the non-electrified longitudinal sections of the raceway. It completes areas equipped with SFC3 electrical segments.
RH2 end cap
Closes the end of the profile. It does not replace the SFC2D or the components of the electrified sections.
Technical specifications
To finish your RH2 installation
Desks and workstations
Finish the ends of RH2 profiles recessed into furniture.
Large conference tables
Complete the finish of your RH2 run by assembling it with the appropriate components.
Preparing the run finish
Identify the open ends to be closed, check the chosen finish, then fix the end caps with the screws supplied, according to the RH2 documentation. An installation containing several independent lengths may require several pairs.
The RH2 is designed to be recessed into furniture. These end caps close the ends of the profile; they do not change its protrusion height and do not indicate the watertightness of the assembly. Any work on the electrical installation must be carried out while disconnected from the power supply by a person qualified in electrical work.
Frequently asked questions
What are these end caps used for?
They close the open ends of the RH2 raceway to conceal the interior of the profile and complete the presentation of the installation.
Are they sold individually?
No, they are sold in pairs, i.e. two end caps, with fixing screws included.
How are they fixed?
RH2 end caps are fixed by screwing. The screws required for their fixing are supplied with the pair.
What is the difference with SH1 end caps?
The role is the same, but each end cap must be chosen for the profile concerned. This data sheet presents the end caps designed for the RH2.
What is the difference with the SFC2D?
The SFC2D closes a non-electrified longitudinal section. The end caps close the ends of the profile. These functions are distinct.
What finishes are available?
Aluminium and Black, depending on the selected variant.
A neat RH2 installation right to the ends.
The pair · Fixing screws included · Aluminium or Black finishes · RH2 racewayThe compact module that turns your trunking into a network connection point
House a Keystone connector (RJ45, USB, HDMI) directly in your EUBIQ SH1 or RH2 trunking. Installation in seconds, sleek aluminium finish, zero wall drilling. The professional, discreet, and modular network solution.
What is the DS4 housing used for?
The DS4 housing is a modular Keystone-format support designed to be recessed into compatible electrical trunking and skirting boards. It acts as an interface between the trunking and the connector of your choice, allowing you to create a neat and functional RJ45 wall socket integrated into the trunking, without drilling into the wall.
It is the ideal solution for network installations in open spaces, meeting rooms, landscaped offices, or any area where network cables need to remain organized and accessible.
Why choose the DS4?
Versatile
Accepts RJ45, USB, and HDMI connectors in standard Keystone format. A single housing for multiple network and multimedia uses.
Immediate installation
Tool-free clipping in seconds. No wall drilling required: the module clips directly into the trunking.
Ultra compact
Only 30 × 27 mm and 16g. Reduced dimensions that fit without cluttering the space available in the trunking.
Sleek finish
Plastic housing with an aluminium finish, available in silver and black. Fits perfectly in both professional offices and home installations.
Technical specifications
Compatible connectors
The Keystone format is a widely used standard in network and multimedia installations. The DS4 housing accepts different types of modules:
RJ45 Cat. 5e / 6 / 6A
For Ethernet network. High-speed wired connection for workstations and network equipment.
USB Keystone
For charging or data transfer. Add a USB port accessible directly from the trunking.
HDMI Keystone
For high-definition video. Ideal for meeting rooms and presentation areas.
Warning: Always check the depth of the Keystone connector you intend to use before purchasing. Some deeper modules may not fit correctly in the trunking depending on the available rear space.
Compatibility with EUBIQ trunking
The DS4 housing is designed exclusively to fit into two trunking models from the EUBIQ range:
SH1 Trunking
337.5 mm brushed aluminium chassis for elegant wall mounting. Ideal for exposed installations in offices and workspaces.
RH2 Trunking
337.5 mm recessed track chassis, aluminium finish. Perfect for recessed installations and custom designs.
These trunking systems are designed to accommodate standardized modules (electrical sockets, RJ45 ports, multimedia connectors). The DS4 clips into them easily, without any specific tools.
Installation in 5 steps
Choose your connector
Select your Keystone module (RJ45, USB, HDMI), verifying the depth is compatible with your SH1 or RH2 trunking.
Clip the module
Insert the Keystone module into the DS4 housing. The locking mechanism is simple and requires no tools.
Insert into the trunking
Place the housing + connector assembly into the available slot in your SH1 or RH2 trunking.
Connect the cable
Connect your network cable to the back of the RJ45 Keystone connector according to T568A or T568B wiring.
Close the trunking
Your integrated RJ45 socket is ready for use, for a clean and professional network installation.
Frequently asked questions
Is the DS4 compatible with RJ45 Cat. 6A connectors?
Yes, provided that the depth of the Cat. 6A Keystone module is compatible with the depth available in the trunking. Check the Keystone core dimensions before purchasing.
Can this housing be used in trunking other than SH1 and RH2?
The DS4 is specifically designed for EUBIQ SH1 and RH2 trunking. Compatibility with other trunking brands (Legrand, Hager, etc.) is not guaranteed.
Does the DS4 housing come with an RJ45 connector?
No, the DS4 housing is sold alone (without a connector). The RJ45 Keystone module must be ordered separately according to your needs (Cat. 5e, 6, 6A, etc.).
How many housings can be installed in one piece of trunking?
The number of housings depends on the number of available slots on your trunking, as well as the other modules already installed (electrical sockets, switches, etc.).
What is the difference from a standard wall-mounted RJ45 socket?
A classic wall-mounted RJ45 socket is recessed into a wall box. The DS4, however, clips directly into surface-mounted trunking (SH1 or RH2), without drilling into the wall. Ideal for offices and professional spaces where recessed installation is not possible.
The EUBIQ DS4 housing turns your trunking into a true network connection point.
Compact, stylish, universal Keystone compatible — it installs in seconds.
Collections featured
- Choosing a selection results in a full page refresh.
- Opens in a new window.