Strong/weak current separation flange - 330 cm for SH1 profile

  • ✅ NFC 15-100 compliance guaranteed – Approved physical separation for the legal coexistence of high and low voltage.
  • ✅ Simplified tool-free installation – Quick installation by manual insertion; no screws or glue required.
  • ✅ Optimal coverage in a single piece – 330 cm without joints to wire an entire room in one go.

28,32 € TTC

23,60 € HT

Pay in 3 installments with no fees using Klarna on purchases of 35 € or more

In stock - Ready to be shipped

28,32 € TTC

23,60 € HT

⚡ NFC 15-100 Standard 🔧 Tool-free installation 📏 330 cm in one piece
High voltage / low voltage separation flange

330 cm — Compatible with SH1 profile exclusively

Create a reliable physical separation between your power cables (230 V) and your data cables (RJ45, telephony, home automation) in one single trunking, in full compliance with the NFC 15-100 standard.

Why separate high voltage and low voltage?

Can you run high voltage and low voltage in the same trunking? Yes — provided you use an approved physical divider. Here is why it is essential:

📋

NFC 15-100 Compliance

The standard requires a physical separation between power cables (230 V) and low-signal cables (RJ45, telephony, etc.).

📡

Zero interference

High voltage cables generate electromagnetic interference that degrades your network, audio, or home automation connections.

🛡️

Enhanced safety

Physical separation reduces risks in the event of a high-voltage cable failure inside the trunking.

✅

Optimized installation

One single trunking is enough, without sacrificing order or safety. Space-saving and aesthetic results guaranteed.

EUBIQ flange features

330 cm
Single-piece length

Covers almost the entire standard floor-to-ceiling height or a common partition length, without intermediate connectors.

300 g
Total weight

Lightweight, easy to handle and position on your own, even at height on a ladder.

SH1
Compatible profile

Designed and dimensioned specifically for the SH1 profile. Check your reference before ordering.

5-step installation

Installation is simple and requires no specific tools. Direct manual insertion into the profile.

1
Prepare your trunking

Ensure the SH1 profile is securely fixed to the wall or ceiling and that all cables are removed or have not yet been installed.

2
Adjust length if necessary

If your run is shorter than 330 cm, cut the flange to the correct size with a hacksaw or suitable wire cutters.

3
Insert the flange vertically

Slide it into the SH1 profile rail until it stops. It positions itself in the center of the trunking to create two sealed compartments.

4
Distribute your cables

High voltage side (230 V cables, power supply) on one side of the flange; low voltage side (RJ45, telephony, HDMI, home automation…) on the other.

5
Close the cover

Installation is complete, clean, and up to code. No screws or glue needed.

Who is this separator for?

🔌

Professional Electricians

  • New electrical installations or renovations
  • NFC 15-100 compliance upgrades for existing installations
  • Wiring for offices and professional premises
🏠

DIY Enthusiasts

  • Housing renovations with surface-mounted trunking
  • Home automation or home network projects
  • Workshop or garage wiring

Full technical specifications

Feature Value
Brand EUBIQ
Length 330 cm
Dimensions (L × W × H) 330 × 2 × 1 cm
Weight 300 g
Compatibility SH1 profile exclusively
Usage High voltage / low voltage separation
Target standard NFC 15-100

Frequently Asked Questions

Can you put high voltage and low voltage in the same trunking without a separator?
No. The NFC 15-100 standard strictly prohibits it. A physical separation is mandatory to prevent interference and ensure the safety of persons and equipment.
Can this flange be cut to the desired length?
Yes, absolutely. The flange is easily cut with a fine hacksaw or a rotary tool. Simply measure your requirement and cut cleanly at a right angle.
Is the flange compatible with EUBIQ profiles other than the SH1?
This flange is designed and dimensioned specifically for the SH1 profile. For any other profile, check the compatible separator references with EUBIQ or your distributor.
Is a special tool required to install it?
No. Installation is entirely manual, by simple insertion into the profile. No screws or glue are necessary.
⚠️

Important note: this product is an electrical installation accessory. Its implementation must comply with the electrical standards in force (NFC 15-100). If in doubt, call a qualified electrician. This product does not in itself constitute a certificate of conformity for your installation.

One trunking, two perfectly separated worlds.
With this 330 cm EUBIQ flange, finally reconcile practicality and electrical compliance.

Add to cart
Caractéristique Valeur
FinishingBrushed aluminum
Attachment typeSurface-mounted
BrandEUBIQ
Reference5011-0300-0533

FAQ6 Questions

FAQ – EUBIQ high/low voltage separator clip for SH1 profile

What is the difference between high and low voltage, and why must they be separated?

High voltage refers to electrical circuits powered by 230V, such as your power outlets, lighting, or household appliances. Low voltage, on the other hand, includes all low-voltage signal cables: computer networks (RJ45), telephony, home automation, audio, video, or even intercom systems. These two types of cables generate very different energy levels, and their cohabitation without physical separation can cause electromagnetic interference that degrades the quality of your network connections or audio signal. Furthermore, the NFC 15-100 standard mandates a physical separation between these two types of wiring when they run in the same cable duct. The EUBIQ separator clip for the SH1 profile meets this exact requirement.

Is this separator clip compatible with all EUBIQ profiles?

No, this separator clip is designed and sized exclusively for the EUBIQ SH1 profile. Its shape and dimensions (330 × 2 × 1 cm) are adapted to the interior of this specific profile to ensure reliable support and a sealed separation between your two wiring compartments. If you are using a different EUBIQ duct model or one from another brand, we recommend that you check the corresponding separator part number with your distributor before placing an order. An unsuitable clip would guarantee neither mechanical stability nor compliance with the NFC 15-100 standard.

Can the clip be cut to a length shorter than 330 cm?

Absolutely. If your duct run is shorter than 330 cm, you can cut the clip to the desired size. A fine hacksaw or a rotary tool like a Dremel is sufficient to obtain a clean and precise cut. We advise you to carefully measure the necessary length and cut square for a clean finish and optimal positioning in the SH1 profile. The lightweight material of the clip (300g for 330 cm) greatly facilitates this operation.

Does installing this clip require any special tools or skills?

No, the installation of this separator clip is accessible to both professional electricians and DIY enthusiasts. No tools are required for the installation itself: simply insert the clip vertically into the SH1 profile rail and slide it into place. It sits in the center of the duct and naturally divides the space into two distinct compartments. If cutting is necessary to adjust the length, a simple hacksaw or rotary tool will do. However, if you have any doubts about your electrical installation as a whole, we recommend calling a qualified electrician, in accordance with the requirements of the NFC 15-100 standard.

Is this clip enough to make my installation compliant with the NFC 15-100 standard?

The EUBIQ separator clip is an essential accessory for meeting the physical separation requirement imposed by the NFC 15-100 standard between high-voltage and low-voltage cables. However, it is just one element of a compliant installation: the quality of the cables used, their installation, the upstream electrical protections, and your entire electrical panel also come into play. This product alone does not provide a certificate of conformity for your installation. In case of doubt or for full compliance, we recommend consulting a certified electrician who can validate your entire installation.

What types of cables can be run on each side of the clip?

Once the clip is in place in your SH1 profile, you have two distinct compartments to use for dedicated purposes. On the high-voltage side, you can run your 230V power cables, such as those for power outlets or lighting. On the low-voltage side, you can group all your signal cables: RJ45 network cables, telephone cables, HDMI cables, home automation, sound system, or intercom cables. This clear organization ensures not only regulatory compliance but also an installation that is legible and easily scalable if you wish to add new equipment later on.

Expert Advice

Mon–Fri 9am–6pm

Fast delivery

Home or pick-up point

GSS Patent

Maximum Security

WHAT OUR CLIENTS SAY ABOUT US

Discover below the reviews left by our hundreds of satisfied customers. These reviews come from verified buyers, and are controlled and verified by Judge.me, acting as a trusted third party between Eubiqeurope and its customers.

4.8 out of 5 stars based on 443 reviews.

Are you a professional ?

Electrician, fitter, furniture maker, kitchen designer...Apply for your professional account now to benefit from your conditions.